Hydraulic Driven Gas Boosters

Hydraulic driven boosters are used at high voltages of over 7kW. The boosters are available in two series, the 100- and 200-series. Both series has single staged double acting and two stage boosters. These boosters are mounted in a lying position. Isolation of the compression chambers from the drive section is provided by three sets of dynamic seals. The intervening two chambers are vented to atmosphere. This design prevents contamination. The design principle is the same as the air driven pumps with a slow reciprocating piston with check valves opening and closing. However an important difference is that there is no switching function installed. HYDMOS constructs hydraulic systems and control systems custom made for these boosters.

Cooling is provided by routing coolant through an individual jacket surrounding the gas barrel. The coolant can be the exhaust hydraulic oil or another fluid.

Calculations for hydraulic driven boosters can be found under the tab DATASHEETS AND CALCULATIONS.

Example of what the model number 120HGT10-165/50 indicates:

120 points out the diameter of the hydraulic cylinder (mm)

T stands for two stage

10 is the stroke length (inches)

165 is the diameter of the first stage piston (mm)

50 is the diameter of the second stage piston (mm)

 

 {gallery}Hydrualdrivna Gasboostrar{/gallery}

 

 Single Staged - Double Acting, the 100-Series, Stroke 6 ”

MODELSupply Pressure Min (bar)  Supply Pressure Max (bar)Outlet Pressure Max (bar) Max. CRDepl. literCPM 
100HGD6-145 3,4 128 128 6 5,11 25
100HGD6-115 3,4 190 190 6 3,13 25
100HGD6-85 6,9 414 448 6 1,76 25
100HGD6-50 6,9 414 931 6 0,66 25

 

Two Staged, the 100-Series, Stroke 6 ”

MODELSupply Pressure Min (bar)Supply Pressure Max (bar)Outlet Pressure Max (bar)Max. CRDepl. literCPM
100HGT6-145/85 3,4 128 448 104 0,88 25
100HGT6-145/50 3,4 128 448 280 0,33 25
100HGT6-115/85 3,4 190 448 64 0,88 25
100HGT6-115/50 3,4 190 931 171 0,33 25
100HGT6-85/50 6,9 414 931 96 0,33 25

 

Single Staged – Double Acting, the 120-Series, Stroke 10 ”

MODELSupply Pressure Min (bar)Supply Pressure Max (bar)Outlet Pressure Max (bar)Max. CRDepl. liter  CPM
120HGD10-165 3,4 128 128 6 11,73 18
120HGD10-85 6,9 414 448 6 2,93 18
120HGD10-50 6,9 414 931 6 1,11 18

 

 

Two Staged, the 120-Series, Stroke 10 ”

MODELSupply Pressure Min (bar) Supply Pressure Max (bar)Outlet Pressure Max (bar)Max. CRDisp liter.CPM 
120HGT10-165/85 3,4 128 448 144 1,47 18
20HGT10-165/50 3,4 128 931 386 0,55 18
120HGT10-85/50 6,9 414 931 96 0,55 18

Want to know more, call us   +46 (0)8 795 52 60